SMARTECH - Fan Coil Units (FCU)

Sort by :    

SEARCH




Chilled Water Ceiling Cassette Units (SCSF Series)

SMARTECH

VIEW MORE

Chilled Water Floor Standing /Ceiling Exposed Units (SCEF Series)

SMARTECH

VIEW MORE

Chilled Water Low Static Ducted Units (SCLF Series)

SMARTECH

VIEW MORE

Chilled Water Medium Static Ducted Unit (SCMF Series)

SMARTECH

VIEW MORE

Chilled Water Wall Mounted Units (SWF Series)

SMARTECH

VIEW MORE

Ducted Belt-Driven Acoustic Fancoils

SMARTECH

VIEW MORE

Ducted Direct-Drive Acoustic Fancoils

SMARTECH

VIEW MORE

High Static Pressures Ducted Direct Drive EC-Motor Plug Fans Fancoils (ECPF-H Series)

SMARTECH

VIEW MORE
Chilled Water Ceiling Cassette Units (SCSF Series)

SMARTECH

• Capacity range: 300CFM to 500CFM (Compact) or 600CFM to 1500CFM (Standard).
• Compact design, simple installation and easy maintenance.
• Unique 3D design of the centrifugal fan ensures extra quiet operation & high efficiency.
• 4-way air supply panel is standard, 360⁰ air supply panel available as an option.
• Built-in drain water pump with 500mm (Compact) & 750mm (Standard) pumping head.
• LED display with error code for easy fault diagnostic.
• Wireless remote with LED display, wired control is optional.
• Air outlets at sides of unit are available. These can be connected by duct to supply air to nearby small rooms.

VIEW MORE

Chilled Water Floor Standing /Ceiling Exposed Units (SCEF Series)

SMARTECH

• Flexible for installation; designed for horizontal/vertical and concealed /cabinet application.
• Ultra thin body, streamlined appearance.
• 220-240V /1ph / 50hz power supply is standard.
• Movable louver for wide angle air flow.
• Air return from the side or below for increased flexibility.
• 3-way electromagnetic valve can be built inside.
• Remote controller is optional.

VIEW MORE

Chilled Water Low Static Ducted Units (SCLF Series)

SMARTECH

• Capacity range: 200~2000CFM.
• Wide external static pressure supplying. Three external static pressure (12Pa/30Pa/50Pa) settings for added flexibility.
• Standard extended drainage pan for protecting your ceiling better.
• Left or right hand piping connections, field convertible.
• Flexible control, remote controller and wired controller are optional.
• A patent design is able to prevent abnormal noise caused by blowing fins.
• Higher efficient heat exchange for complete contranatant flow.
• Return air plenum and filter are standard.
• Fresh air supply makes life healthier and more comfortable.
• 220-240V/1Ph/50Hz power supply is standard.

VIEW MORE

Chilled Water Medium Static Ducted Unit (SCMF Series)

SMARTECH

• High air volume, high static pressure and high capacity.
• High-pressure centrifugal fans.
• Easy to clean and change the air filter.
• Standard extended drainage pan for protecting your ceiling better.
• Return air plenum and filter are standard.
• Four-speed motor with one reserved for more choice.
• Pipe connection from left or right can be selected (in factory).
• 220--240V/1Ph/50Hz power supply is standard.
• Flexible control, remote controller and wired controller are optional.

VIEW MORE

Chilled Water Wall Mounted Units (SWF Series)

SMARTECH

• LED display display.
• Crossflow fan creates quiet and comfortable environment.
• Multi piping connection; left/ right/ rear, to suit any installation requirement.
• Easy maintenance with removable front panel.
• 220-240V/1Ph/50Hz power supply is standard.
• Built-in 3 way electromagnetic valve.
• Wireless remote control with LED display is standard,wired control is optional.

VIEW MORE

Ducted Belt-Driven Acoustic Fancoils

SMARTECH

• Ducted DBA fan coil units (FCU) come with various capacity sizes from 28MBH to 280MBH.
• The air flow rate ranges from 800CFM to 8400CFM.
• Each FCU comes with Totally Enclosed Fan-Cooled (TEFC) motors and belt-driven forward curve centrifugal blowers. The FCUs shall be suitable for application where external static pressure may vary from 0.5” w.g. to a maximum of 2.5” w.g. without excessive noise.
• These FCUs are readily adapted to a wide variety of ceiling mounted installation where low noise break-out and ease of access to internal components for preventive maintenance are important criteria for consideration.
• Typical unit can accommodate a cooling coil from 3 rows deep to 6 rows deep, either of chilled water or DX type (using refrigerant R410A).
• An unlimited selection of factory installed control systems is available for DBA models.

VIEW MORE

Ducted Direct-Drive Acoustic Fancoils

SMARTECH

• Ducted DDA fan coil units (FCU) come with various capacity sizes from 19MBH to 120MBH.
• The air flow rate ranges from 600CFM-3500CFM.
• Each FCU comes with Permanent Split Capacitor (PSC) motors and direct drive forward curve centrifugal blowers. The FCUs shall be suitable for application where external static pressure may vary from 0.2” wg to a maximum of 0.7” wg without excessive noise.
• These FCUs are readily adapted to a wide variety of ceiling mounted installation where low noise break-out and ease of access to internal components for preventive maintenance are important criteria for consideration.
• Typical unit can accommodate a cooling coil from 3 rows deep to 6 rows deep, either of chilled water or DX type (using refrigerant R410A).
• An unlimited selection of factory installed control systems is available for DDA models.

VIEW MORE

High Static Pressures Ducted Direct Drive EC-Motor Plug Fans Fancoils (ECPF-H Series)

SMARTECH

• Ducted ECPF fan coil units (FCU) come with various capacity sizes from 21MBH to 280MBH.
• The air flow rate ranges from 600CFM to 8400CFM.
• Each FCU comes with high efficiency EC motors and direct coupled to centrifugal plug fans.
• The FCUs shall be suitable for application with external static pressure of up to 2.0” w.g. without excessive noise.
• These FCUs are readily adapted to a wide variety of ceiling mounted installation where low noise break-out and ease of access to internal components for preventive maintenance are important criteria for consideration.
• Typical unit can accommodate a cooling coil from 3 rows deep to 6 rows deep, either of chilled water or DX type (using refrigerant R410A).
• Each FCU shall be provided with a factory mounted speed controller to allow manual adjustment for fan-motor speed to meet specified side airflow rates versus external static pressure requirements.

VIEW MORE