LG - Air Cooled Variable Refrigerant Flow

Sort by :    

SEARCH




Multi V 5 Heat Pump

LG

VIEW MORE

Multi V 5 Heat Recovery

LG

VIEW MORE

Multi V S

LG

VIEW MORE
Multi V 5 Heat Pump

LG

• Min. EER above 4.00, except single module 26 HP is 3.75.
• Single outdoor unit can provide up to 26HP.
• Providing up to 96HP by combination.
• 380-415V/3Ph/50Hz power supply is standard.
• Sound pressure level range: 58 dB(A) ~ 71 dB(A).
• Dual Sensing Control senses both humidity and temperature for comfort operation.
• Compressor with wider frequency range from 10Hz to 165Hz.
• Build-in oil level sensor to balance and manage oil level in both compressors and run the oil recovery operation only if necessary.
• High Pressure Oil Return (HiPOR™) minimizes energy loss with direct oil return.
• Fan with Biomimetic Technology increase air flow rate up to 10% while reducing power consumption up to 20%.
• LG’s “Ocean Black Fin” 4 side heat exchanger able to perform in corrosive environment.

VIEW MORE

Multi V 5 Heat Recovery

LG

• Min. EER 3.60.
• Single outdoor unit can provide up to 26HP.
• Providing up to 96HP by combination.
• 380-415V/3Ph/50Hz power supply is standard.
• Sound pressure level range: 58 dB(A) ~ 71 dB(A).
• Able to provide heating and cooling at the same time with the help of heat recovery unit.
• Dual Sensing Control senses both humidity and temperature for comfort operation.
• Compressor with wider frequency range from 10Hz to 165Hz.
• Build-in oil level sensor to balance and manage oil level in both compressors and run the oil recovery operation only if necessary.
• High Pressure Oil Return (HiPOR™) minimizes energy loss with direct oil return.
• Fan with Biomimetic Technology increase air flow rate up to 10% while reducing power consumption up to 20%.
• LG’s “Ocean Black Fin” 4 side heat exchanger able to perform in corrosive environment.

VIEW MORE

Multi V S

LG

• Single phase power supply model range is 3HP to 6HP.
• Three phase power supply model range is 8HP to 12HP.
• EER range: 3.20 to 4.38.
• Sound pressure level range: 50 dB (A) ~ 60 dB (A).
• Operation response gets faster and more accurate with pressure sensor.
• Variable heat exchanger circuit able to selects the optimal paths for both heating and cooling operation and this increase efficiency up to 5%.
Heat exchanger efficiency is improved up to 5% with wide louver plus fin.
• Can optimizes energy efficiency by controls refrigerant temperature according to indoor, outdoor and setting temperature.
• Compressor with wider frequency range from 15Hz to 150Hz.
• Compressor reliability is maximized with 6 by-pass valve to prevent compressor damage caused by excessively compressed refrigerant.

VIEW MORE